Operation
52
6 OPERATION
6.1 CONTROL
Control of the module is via push buttons mounted on the front of the module with
START INHIBIT/RESET
( )
, MANUAL
( )
, AUTO
( )
, MODE
( )
, ALARM MUTE
( ),
LATEST TRANSFER INFORMATION
( ),
CLOSE/OPEN S1
( )
and CLOSE/OPEN S2
( )
functions. For normal operation, these are the only controls which need to be operated. The smaller
push buttons are used to access further information such as mains voltage or to change the state of
the load switching devices when in manual mode. Details of their operation are provided later in this
document.
The following descriptions detail the sequences followed by a module containing the standard ‘factory
configuration’. Always refer to your configuration source for the exact sequences and timers observed
by any particular module in the field.
CAUTION:
CAUTION: CAUTION:
CAUTION: -
--
-
The module may instruct an engine start event due to external influences.
The module may instruct an engine start event due to external influences. The module may instruct an engine start event due to external influences.
The module may instruct an engine start event due to external influences.
Therefore, it
Therefore, itTherefore, it
Therefore, it
is possible for the engine to start at any time without warning. Prior to
is possible for the engine to start at any time without warning. Prior to is possible for the engine to start at any time without warning. Prior to
is possible for the engine to start at any time without warning. Prior to
performing any maintenance on the system, it is recommended that steps are taken to
performing any maintenance on the system, it is recommended that steps are taken to performing any maintenance on the system, it is recommended that steps are taken to
performing any maintenance on the system, it is recommended that steps are taken to
remove the battery and isolate supplies.
remove the battery and isolate supplies.remove the battery and isolate supplies.
remove the battery and isolate supplies.
NOTE:
NOTE: NOTE:
NOTE: -
--
-
This control
This controlThis control
This control
module
modulemodule
module
has PLC functionality buil
has PLC functionality builhas PLC functionality buil
has PLC functionality built in.
t in.t in.
t in.
This can have change the
This can have change the This can have change the
This can have change the
standard operation when used.
standard operation when used.standard operation when used.
standard operation when used.
(
((
(Default configuration the no PLC is set. See software
Default configuration the no PLC is set. See software Default configuration the no PLC is set. See software
Default configuration the no PLC is set. See software
manual for more information)
manual for more information)manual for more information)
manual for more information)
Seitenansicht 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 81 82

Kommentare zu diesen Handbüchern

Keine Kommentare